ESS Battery Packs
High-Voltage Industrial & Commercial Energy Storage Battery
Our High-Voltage LFP system powers industrial hubs. It offers 314Ah-628Ah scalability to ensure reliable, high-capacity energy storage.
- High-Voltage Scalability: Flexible 314–628Ah design to meet large-scale industrial energy demands.
- Smart Grid Integration: Optimized for peak shaving and reliable backup power in commercial hubs.
- Industrial LFP Safety: Premium LiFePO4 cells ensure 4000+ cycles and high thermal stability.
- Products
EV Battery Packs
E-Bike Battery Packs
Industrial & Commercial EV Batteries
ESS Battery Packs
Industrial & Commercial Energy Storage Battery Specifications
Our 314–628Ah specs cover high-voltage, cycle life, and BMS data. These details ensure safety and efficiency for industrial energy storage.
Model Number
Model Number 1
CC
200A
Place of Origin
Hubei, China
Condition
New
Weight
253kg
Voltage
355V
Place of Origin
Hubei, China
Condition
New
Weight
253kg
Voltage
355V
Key Features of the Industrial & Commercial Energy Storage Battery
Our high-voltage LFP system features smart BMS and modular 314–628Ah design. It ensures high safety and efficiency for industrial grids.
High-Voltage System Design
Our high-voltage LFP system reduces energy loss. It is perfect for large industrial grids needing peak efficiency.
High-Voltage
Output
Low
Energy Loss
Scalable Modular Capacity
Expand storage from 314Ah to 628Ah easily. This modular design fits growing commercial energy storage demands.
628Ah
Max Capacity
Modular
Scaling
Smart Industrial BMS Control
The advanced BMS monitors every LFP cell. It ensures safety and stability for high-power commercial operations.
Active
Balancing
24/7
Monitoring
Ultra-Long Cycle Reliability
Built for durability, this system offers 6000+ cycles. It provides a decade of stable power for heavy industry.
4000+
Deep Cycles
8-10 Year
Lifetime
Peak Shaving Efficiency
Optimize your grid costs with peak shaving. This battery stores cheap energy to power your factory during peaks.
Cost
Optimization
Peak Shaving
Tech
Rapid Discharge Capability
Support high-current loads without voltage drops. This 314–628Ah bank is built for heavy commercial machinery.
High
Discharge Rate
Stable
Current
Industrial & Commercial Energy Storage Battery Advantages
Our 314–628Ah LFP systems cut grid costs via peak shaving. They offer high safety and 4000+ cycles for reliable industrial power.
01Peak Shaving and Cost Reduction
Peak Shaving and Cost Reduction
Our 314–628Ah systems store power during off-peak hours. This significantly reduces high electricity bills for large industrial hubs.
- Save on operational costs by using stored energy during expensive peak periods.
02High-Voltage Efficiency Standards
High-Voltage Efficiency Standards
The high-voltage LFP design minimizes heat and energy loss. It provides superior power conversion for heavy commercial machinery.
- Experience higher energy throughput and reduced cooling needs in your factory.
03Unmatched 6000+ Cycle Reliability
Unmatched 6000+ Cycle Reliability
These industrial-grade LFP packs offer over 4000 deep cycles. They ensure your energy investment lasts for more than a decade.
- Maintain consistent power performance over thousands of daily charge cycles.
04Emergency Backup Power Security
Emergency Backup Power Security
Protect your facility from sudden grid blackouts. Our 628Ah system offers high-capacity backup to keep production lines running.
- Avoid costly downtime with instant power switching during unexpected outages.
05Smart Grid Interaction Ability
Smart Grid Interaction Ability
Integrated smart BMS allows for seamless grid interaction. It optimizes energy flow and supports local utility grid stability.
- Smart communication protocols ensure safe and efficient power distribution.
06Sustainable Green Energy Impact
Sustainable Green Energy Impact
Reduce your carbon footprint by storing clean solar power. This 314–628Ah system supports your company’s ESG and green goals.
- Transition to eco-friendly operations with reliable large-scale LFP storage.
Industrial & Commercial Energy Storage Battery Video
Watch our 314–628Ah LFP system in action. This video shows its high-voltage design and how it powers large industrial and commercial hubs.
Installation Instructions for the Industrial & Commercial Energy Storage Battery
Set up your 314–628Ah high-voltage LFP system safely. This guide covers wiring and BMS sync for stable industrial energy storage.
01
Industrial Site Preparation

Industrial Site Preparation
Select a reinforced concrete floor for your 314–628Ah system. Ensure the industrial space has active cooling and fire safety gear.
- Verify the floor load-bearing capacity exceeds the total weight of the high-voltage cabinets.
- Maintain a minimum distance of one meter from other machinery to ensure safe maintenance access.
- Install the battery racks in a temperature-controlled environment to protect LFP cell health.
02
High-Voltage DC Wiring

High-Voltage DC Wiring
Connect the high-voltage DC cables using insulated tools. Correct torque is vital for the 628Ah system to prevent overheating.
- Use professional-grade torque wrenches to tighten all terminal bolts to specified standards.
- Double-check cable insulation for any damage before connecting to the high-voltage busbar.
- Ensure the positive and negative cables are clearly labeled and routed through safety conduits.
03
BMS and Communication Link

BMS and Communication Link
Link the master BMS to your industrial energy management system. This ensures 24/7 monitoring of the 314–628Ah battery bank.
- Connect the shielded communication cables to the RS485 or CAN ports on the central controller.
- Configure the IP addresses for each battery module within the local industrial network.
- Test the data feed to confirm that voltage, current, and temperature are reporting correctly.
04
System Parallel Expansion

System Parallel Expansion
For 628Ah capacity, align multiple 314Ah units. Proper addressing is required to balance the high-voltage load across modules.
- Set the unique identification ID for each battery rack using the physical DIP switches.
- Ensure all battery modules are at the same state of charge before initiating parallel operation.
- Use matched power cables to maintain equal resistance and balanced current across the system.
05
System Startup and Commission

System Startup and Commission
Follow the sequential power-on steps for the LFP system. Verify that the high-voltage output matches the commercial grid specs.
- Turn on the internal BMS power first, followed by the main DC circuit breakers in sequence.
- Run the system in standby mode for ten minutes to check for any early warning fault codes.
- Gradually introduce the industrial load to verify stable discharge performance of the 628Ah bank.
Industrial & Commercial Energy Storage Battery Certification
Our high-voltage 314–628Ah LFP systems meet CE, UL, and IEC standards. We guarantee safety and quality for industrial energy storage.
UN38.3 Certification
UN38.3 is a UN safety standard for lithium batteries, requiring strict tests to ensure safe global transport and reduce risks like overheating, short circuits and leakage during delivery.
MSDS
MSDS is an essential safety document outlining hazards, handling and emergency procedures for battery materials, ensuring safe use and transport while meeting global safety and regulatory requirements.
EU RoHS 10 certificate
The EU RoHS 10 certificate proves a product meets EU standards restricting 10 hazardous substances, ensuring it is safe, eco-friendly and legally compliant for sale in Europe.
CE Certification
The CE certificate is a mandatory EU safety mark, confirming compliance with health, safety and environmental standards for legal sale in the European market.
Industrial & Commercial Energy Storage Battery Technical Support
Our team supports your 314–628Ah high-voltage setup. We provide BMS tuning and grid integration to keep your industrial power safe.
High-Voltage System Design Assistance
Our engineers help plan your 314–628Ah LFP layout. We ensure optimal high-voltage efficiency for your industrial site.
Professional BMS Firmware Updates
We provide remote BMS tuning for 628Ah systems. This optimizes cell balancing to extend your battery’s service life.
Seamless Smart Grid Integration
Get expert help linking your 48V-HV system to the grid. We support peak shaving setup for lower commercial costs.
24/7 Remote Monitoring and Diagnosis
Access real-time data for your LFP storage bank. Our team helps resolve any industrial power alerts immediately.
Modular System Scaling Support
Need to expand from 314Ah to 628Ah? We provide parallel wiring guides for a safe and easy commercial upgrade.
On-Site Safety Training Programs
We offer safety training for your technical staff. Learn to manage 314–628Ah high-voltage systems with confidence.
Contact Us
Contact our experts for professional battery solutions. We are here to support your power needs with reliable service and expertise.